Many piping systems lack adequate isolation points. When you need to add a permanent isolation valve to an existing line — without shutting down — insert valve technology is the solution. Millennium offers the EZ Valve, which is classed as the best choice for emergency repairs and the smartest solution for planned and emergency pipeline maintenance on 4" to 24" diameter lines.
This in-line insertion valve can be installed on horizontal or vertical lines and typically requires a single excavation, enabling fast installation, fewer disruptions to business and residents, and lower costs and risk for owners and operators. It is rated for potable water, food and beverage manufacturing, and industrial/commercial systems.
Unlike line stops, which provide temporary isolation, insert valves remain in the pipeline permanently. They can be operated like any other valve for future maintenance, modifications, or emergency isolation. Our crews handle the entire process — from installation to commissioning — on live, pressurized systems.
EZ Valve Benefits
- No water shutoff required during installation
- No fines for water shutoff
- No boil orders or customer notices
- No risk of plugging the line with a cut coupon
- No loss of pipe integrity
- Four times quicker to install than other valves on the market
- Only one excavation required for water line repair
Installation
- Can be installed on all common pipe materials
- Installs on horizontal or vertical lines, at any angle
- Customizable for special applications (sleeves to meet steel pipe ODs)
- The valve bonnet can be removed after repair or remain in place as a permanent functioning part
Safety & Specifications
- Epoxy coated
- Stainless steel fasteners for secure positioning
- Working pressure of 250 PSI — tested pressure to 375 PSI
- Components are WRAS Certified, meet AWWA C509/C515 Standards, and are UL Classified to NSF/ANSI Standard 61, Drinking Water System Components — Health Effects
Applications
- Adding isolation valves to existing pipelines
- Replacing failed or inoperable valves without shutdown
- Emergency isolation point installation
- Municipal water distribution system upgrades
- Process piping isolation improvements
- Pipeline sectionalizing for maintenance access